NOT KNOWN FACTUAL STATEMENTS ABOUT DP50RB

Not known Factual Statements About Dp50rb

Not known Factual Statements About Dp50rb

Blog Article

1.two.two Warning Labels Warning Labels Indicating Remember to cautiously read through this manual ahead of use product. The next labels are a. Never area the device with a sloped floor. Or else the offered if the technique product could slide, resulting in own damage or even the unit operates Along with the mobile malfunction.

The consumer is just not allowed to open the addresses and panel with the program, neither Take note: gadget disassemble is permitted. To ensure the procedure performance and basic safety, only Mindray engineers or engineers approved by Mindray can perform maintenance.

Notice: To the keep an eye on, the brightness adjustment comes ahead of distinction. Right after readjusting the observe’s contrast and brightness, modify all preset and peripheral settings.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Slice off cable ties connecting the principle unit on the Show by diagonal cutting pliers, after which pull out the corresponding cable plugs.

Mindray’s new era of black & white ultrasound process, DP-fifty Skilled, is provided with advanced imaging systems enabling further penetration and speedier graphic acquisition with larger resolution.

S. must present the Section using an electronic mail deal with if they may have 1. The e-mails delivered could be used for official interaction Along with the licensee. Nevertheless e-mail addresses are public record. If you do not wish to provide a personal handle, be sure to give the Section by having an electronic mail handle which may be produced available to the public. Make sure you see our Chapter 455 web site to find out For anyone who is impacted by this change.

Uncover far better diagnostic information by means of prolonged look at of the anatomical construction on all convex probes.

Permits utilization of a number of scanned angles to sort a single impression, resulting in Increased distinction resolution and improved visualization

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Take a look at Move: Do changes as the way in tests the most depth. File the gap by 20mm each segment around the longitudinal targets line using the measurement caliper; Pick the worth with the greatest mistake (to 20mm), work out the accuracy using the method down below The measurement caliper ought to be positioned for the upper edge of the target, Take note:... Web site seventy nine Transverse geometric positioning accuracy  Examination Move: Go over the scan area on the phantom with drinking water or few gel, Carefully Call the probe Together with the scan area Modify the depth, building the transverse targets to be displayed inside the impression. Modify the focus level being posited beside the transverse targets (the standard isn't obvious) Alter parameters like acquire, TGC, creating Every single transverse targets being Plainly displayed. Web page eighty 5.five.2.4 Blackout Location Check Stage: Include the scan area with the phantom with water or couple gel, Carefully Get in touch with the probe With all the scan surface Change the depth at a decreased worth, and established the main target at the nearest location to the scan surface. Reduce the worth of parameters like AP, Acquire right until the track record sound just is often noticed. Web site eighty one: Application Upgrade And Upkeep

Soon after productive connection, the freshly additional network printer name is going to be demonstrated from the printer driver record. Be aware: In advance of join the community printer, make sure the ultrasound program along with the printer are in precisely the same community domain, and the community is working Usually. The IP address and the server identify need to be valid, e.g. Website page 47 DICOM Location  Enter the AE Title with the ultrasound technique, port and PDU according to the actual situation, and then click on [OK] to exit the display screen.

.. Web page 161 The indicator within the printer Errors occur in the event the adapter turns orange, and also the printing printer adapter runs. Disconnect and connect the fails. power adapter, energy on the printer adapter once again, and validate if the printing is normal after one moment. Page 163: Electrical Protection Inspection

Be aware: Dp50rb In advance of inserting the connector in the probe port, inspect the connector pin. If your pin is bent, don't use the probe right until it has been inspected / repaired / replaced. Putting in Peripherals For your versions of your supported peripherals, please make reference to “2.

Following replacing the CPU module, vital file should be generated Once more according to the new MAC deal with and penned into HDD of your machine. Or else, the configuration perform of the product or service will likely be lost. After removing the CPU module, Remove panhead screws with washers (twelve M3X6) fastened on the principle device box, you might take from the board. Web site 118 Figure 8-29 Disassemble the Control Panel Assembly (one) Keep the upper edge of control panel assembly, and open up up the user interface. Determine eight-thirty Disassemble the Control Panel Assembly (2) Following eliminating a person countersunk head self-tapping screw PT3X10 fastened on the user interface and just take out the plug in the keyboard and the principle device connecting cables, you could possibly remove the control panel assembly.

Take note: Make certain that you could pull out and push in to the IO board sockets vertically when pulling out and assembling the IO board assembly over the place of the deal with. Eliminate panhead screws with washers M3X6 (4) accustomed to safe the IO board, then you might get out the IO board. Site 116 Clear away panhead screws with washers (two M3X6) which might be fastened on the key device, get out the upper baffle and after that pull out two cables connecting the main board to the ability module assembly.